| Spesifikasi | | | | | | | | |
| pH | | | | | mV | |
| | › | Range | | : | -2… +16 pH | | | › | Range | : | ±2000 mV
| | › | Resolution | | : | 0.001 pH | | | › | Resolution | : | 0.1 mV
| | › | Accuracy | | : | 0.1& ± 1 digit | | | › | Accuracy | : | 0.1% ± 1 digit
| | › | Calibration | | : | 1…5 points | | | › | Calibration | : | 1 point
| | › | Buffer | | : | 9 pre-programmed 5 user spectifled | | | | | |
| | › | Temprature compensation: -30… + 130°C | | | | | Resistivity | |
| | › | ISO-pH | | : | 6…8 pH | | | › | Range | : | 0… 200mΩ. Cm
| | › | slope | | : | 80… 120% | | | › | Resolution | : | 1Ω. Cm
| | › | zero point (Eo) | | : | ±999 mV | | | | | |
| Dissolved Oxygen | | | | | Salinity | |
| | › | Range | | : | 0… 60mg (0…600%) | | | › | Range | : | 0… 70ppt
| | › | Resolution | | : | 0,01 mg/ (0.1%) | | | › | Resolution | : | 0,1 ept
| | › | Accuracy | | : | 1% ± 1 digit | | | | | |
| | › | Calibration | | : | 1 point | | TDS | |
| | › | Temperature Compensation | | : | 0…50°C | | | › | Range | : | 0…100g/1
| | › | Salinity compensation | | : | 0…40ppt | | | › | Resolution | : | 0,01 mg/ 1
| | › | Air pressure compensation | | : | 600… 1300hPa | | | | | |
| | | | | | | | Temperature | |
| Conductivity | | | | | | › | Range | : | 30… +130°C
| | › | Range | | : | 0…2000 rnS / cm | | | › | Resolution | : | 0.1°C
| | › | Resolution | | : | 0.001 uS / cm | | | › | Accuracy | : | 0.3°C
| | › | Accuracy | | : | 0.5% f. s. of range | | | › | Calibration | : | 1 point
| | › | Calibration | | : | 1…3 points | | | | | |
| | › | Standards | | : | 0.01/0.1/1M KCI 3 User specifled | | Air Pressure | |
| | › | Cell constant | | : | 0.05…15.0 cm | | | › | Range | : | 600…. 1300hPa
| | › | temprature compensation | | : | -30… +130°C | | | › | Calibration | : | 1 point
| | › | Reference temperature | | : | 20° – 25 °C | | | | | |
| | › | Temperature coefficient | | : | natural waters (en 27888) | | Input | |
| | › | Range lock | | : | P | | | › | Measurement | : | BNC, 10² Ω
| | › | Capacitive compensation | | : | P | | | › | Temperature | : | 2 banana, for pt 1000
| ● | Display | : | LCD 128 x 64 pixel, Whitebacklight, hold function, selectable resolution,
| | | | Real time clock
| ● | Language | : | Bahasa Indonesia, English , Nederlands, Francais, Deutsch
| ● | Analog Output | : | Recorder 0 – 2 V1 programmable
| ● | RS232 | : | Interface with printer or PC, Baud Rate: 300 – 19200 b/s
| ● | Data logging | : |
| | – Values | : | 3600+°C /date/ time
| | – Modes | : | all
| | – Manual or timed | : | P
| | – Interval | : | all…9999 s
| ● | Security | : | Indectification number & Password protection
| ● | Ambient conditions | : | Temperature 0 – 40° C, humidity 0 – 95% non condensing
| ● | Power Supply | : | Mains 210 – 250 VAC, 50/60 Hz, low voltage 9 – 15 VDC, baterai 4×1.2 V, NiMH
| ● | Komunikasi Perangkat | : | NFC
| ● | Dimention | : | WxDxH 12x25x5 cm
| ● | Weight | : | 600 g
| ● | Include supply | : | Meter kit complete : C6010 + pH/ATC electrode + Conductivity/ATC electrode +
| | | | Dissolved Oxygen electrode + 2×50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCl)
| | | | + 50 ml Conductivity standard (0,01 M KCl) + Carrying Case, EHIS V2
| ● | Manual Book | : | Bahasa Indonesia & Bahasa Inggris
| ● | Telah memperoleh sertifikat ISO | |