| ● | Omnidirectional telescopic probe and multifuction probe :
| | Parameter | Range
| ● | air velocity | 0,15 to 5 m/s
| ● | Temperature | 0 to 50 °C
| ● | Hygrometry | 5 to 95 %RH
| ● | CO/temperature | 0 to 500 ppm and -20 to 80 °C
| ● | CO2/temperature | 0 to 5,000 ppm – 20 to 80 °C
| ● | gas leak detection | 0-10000 ppm
| ● | Sensing elements | | | | | | | | | | | | | | | | | | | | | | | | |
| | Pressure modules | : | Piezoresistive sensor
| | | | Overpressure allowed ±500 Pa : 250 mbar
| | | | Overpressure allowed ±2500 Pa : 500 mbar
| | | | Overpressure allowed ±10,000 Pa : 1,200 mbar
| | | | Overpressure allowed ±500 mbar : 2 bar
| | | | Overpressure allowed ±2,000 mbar : 6 bar
| ● | Hotwire | : | Thermistance with a negative temperature coefficient.
| ● | Ambient temperature | : | Pt100 1/3 Din.
| ● | Ø 70 and 100 mm vane probes | : | Hall effect sensor
| ● | Ambient temperature | : | Pt100 class A.
| ● | Ø 14 mm vane probe | : | Proximity sensor
| ● | Ambient temperature | : | Pt100 class A.
| ● | Hygrometry/Temp. Probe | | capacitive sensor, Pt100 1/3 DIN
| ● | Thermocouple probes | : | type K, J and T class 1
| ● | Pt100 probes Smart-plus | : | Pt100 class 1/3 Din
| ● | Climatic conditions module | |
| | › | Hygrometry | : | capacitive sensor
| | › | Temperature | : | semiconductor sensor
| | › | Air pressure | : | piezoresistive sensor
| ● | Air quality probes | |
| | › | CO2 | : | NDIR sensor
| | › | CO | : | electrochemical sensor
| | › | Temperature | : | Pt100 class A
| | › | Hygrometry | : | capacitive sensor
| ● | Climatic conditions module | |
| | › | Hygrometry | : | capacitive sensor
| | › | Temperature | : | semiconductive sensor
| | › | Air pressure | : | piezoresistive sensor
| ● | Multifunction probe | |
| | › | Air velocity | : | Thermistance with a negative temperature coefficient.
| | › | Hygrometry/Temp. | : | capacitive sensor, Pt100 1/3 DIN
| ● | Omnidirectional Probe | |
| | › | Air velocity
Hygrometry/Temp. | : | Thermistance with a negative temperature coefficient.
| | › | : | capacitive sensor, Pt100 1/3 DIN
| ● | Tachometry probe | |
| | › | Optical | : | optical sensor
| | › | Contact | : | optical probe with ETC adaptor
| ● | Gas leak detection probe | |
| | › | Ch4′ hydrocarbon and LPG | : | electrochemical sensor
| ● | Instrument connections | |
| | › | On the top | : | 2 secured mini-DIN connectors for SMART-Plus probes
| | › | Left side | : | 1 USB port for KIMO cable only
| | | | | 1 power supply plug
| ● | Module connections | |
| | › | Thermocouple | : | 4 inputs for compensated miniature
| | | | | plug of thermocouple type K, J or T Class 1 (as per IEC 584-3norm)
| | › | Pressure | : | 2 pressure connectors Ø 6.2 mm made of nickelled brass.
| | | | | 2 threaded pressure connectors Ø 4.6 mm made of nickelled brass
| | | | | + 1 thermocouple temperature input for miniature connectors
| | › | Current / voltage module | : | 2 stereo jacks
| ● | Display | : | Graphic display 320×240 pixels
| | | | Dim. 70 x 52 mm, color display
| | | | Display of 6 measurements (including 4 simultaneously)
| ● | Housing IP54 | : | IP54, ABS shock-proof
| ● | Keypad | : | Metal-coated, 5 keys, 1 joystick
| ● | Conformity | : | Electromagnetical compatibility
| | | | (NF EN 61326-1 norm)
| ● | Power supply | : | 4 alkaline batteries 1.5V LR6
| ● | Operating environment | : | Neutral gas
| ● | Operating temperature | : | from 0 to 50°C
| ● | Storage temperature | : | from -20 to +80°C
| ● | Auto shut-off | : | adjustable from 0 to 120 min
| ● | Weight | : | 380g
| ● | Languages | : | French, English, Dutch, German, Italian, Spanish,
| | | | Portuguese, Swedish, Norwegian, Finn, Danish
| | Environtmental and Health Integration System (EHIS)
| • | Login user admin sebagai induk Instansi dapat menambah login untuk anggota dengan jumlah tak terbatas,
| | sebagai upaya pemantauan kegiatan pengujian dilapangan.
| • | Laporan yang tersimpan setiap instansi yang ditampilkan tanggal, nama alat, propinsi dan tempat pengujian
| | dapat di download sebagai file format pdf dan dapat langsung diemail (dalam satu software) apabila
| | diperlukan.
| • | Hasil uji pemeriksaan menampilkan: 1. Data pengambilan sampel seperti: nama tempat instansi; provinsi;
| | kota/kabupaten; alamat; lokasi (koordinat gps); tanggal, waktu, lama, petugas pengambilan sampel.
| | 2. Hasil pemeriksaan seperti: tanggal dan tempat uji laboratorium; acuan NAB yang sudah terdapat pilihan
| | menu NAB yang digunakan: Permenkes No. 1077 Tahun 2011 Pedoman penyehatan udara dalam ruang rumah,
| | Nomor 1405/Menkes/SK/XI/2002 persyaratan kesehatan lingkungan di perkantoran dan industri, No. 1204
| | Persyaratan kesehatan lingkungan rumah sakit, Pemerkes No.492 tahun 2010 tentang kualitas air minum.
| | 3. Kesimpulan terhadap hasil uji ditampilkan otomatis sesuai acuan NAB ataupun di input manual. Form tanda
| | tangan petugas dan pimpinan instansi, seksi atau bidang.
| • | Terdapat berbagai menu seperti: Data pengujian (Air, Laboratorium, Makanan dan Minuman, Sanitasi
| | Lingkungan, Tanah, Udara, Vektor, dll), Parameter, Profil, Anggota, Instansi, Berita Lokal dan Internal.
| • | Semua input hasil pemeriksaan tersebut dapat dilihat atau diberikan kepada berbagai instansi lainnya
| | apabila pengaturan publish diizinkan.
| • | Aplikasi ini dapat dijalankan menggunakan smartphone Android ataupun menggunakan Notebook, Personal
| | Computer, Handphone pada aplikasi browser secara online.
| • | Manajemen pengaturan pengukuran area, dari area besar sampai area terkecil dalam satu laporan mensupport
| | gambar situasi lingkungan, kondisi dari berbagai arah dan sudut pandang
| • | Aplikasi dapat mudah di cari, download dan di upgrade melalui Google Play Store.
| ● | Supply with :
| | Portable evolutive multi-function instrument with backlit digital color display. Supplied with voltage/current
| | module (0 to 10 V – 4-20 mA), voltage and current input cables, 2 Pt100 channels (-100 to 400°C ), PC output,
| | 1 battery charger with 2 sets of reloadable batteries, 2x1m of black & white silicone tube, stainless steel tube
| | diam. 6mm length 100mm, adjusting certificate, Omnidirectional telescopic probe for air velocity,Temperature,
| | Hygrometry probe, Multi-function CO/CO2/temperature probe, Gas leak detection probe and Kartu Garansi,
| | Manual Bahasa Indonesia, EHIS V2 (Environment and Health Integration System) and Hard Carrying case.