| ● | Spectral response | | | | : | 8 -14 μm | | | | | | | | | | | | | | | | | |
| ● | Optical | | | | | | | | : | D.S : 30:1 (50 mm at 1500 mm) | | | | | | | | | | |
| ● | Response time | | | | | : | Less than 1 second | | | | | | | | | | | | | | |
| ● | Temperature range | | | : | From -50 to +850°C | | | | | | | | | | | | | | |
| ● | Accuracy* | | | | | | | : | From -50 to -20°C : ±5°C | | | | | | | | | | | | |
| | | | | | | | | | | | | From -20 to +200°C : ±1.5% of reading ±2°C | | | | | | |
| | | | | | | | | | | | | From +200 to +538 °C : ±2% of reading ±2°C | | | | | | |
| | | | | | | | | | | | | From +538 to +850°C : ±3.5% of reading ±5°C | | | | | |
| ● | Display resolution | | | | : | 0.1 C° | | | | | | | | | | | | | | | | | | |
| ● | Emissivity | | | | | | | : | Adjustable from 0.10 to 1.00 | | | | | | | | | | | |
| | (pre-set at 0.95) | | | | | | | | | | | | | | | | | | | | | | | | | |
| ● | Over range indication | | | : | Display indication : « -0L » for a negative | | | | | | | |
| | | | | | | | | | | | | over range, « 0L » for a positive over range. | | | | | | |
| ● | Laser sighting | | | | | | : | Wavelength : 630-670 nm | | | | | | | | | | | | |
| | | | | | | | | | | | | Output < 1mW, Class 2 (II) | | | | | | | | | | | | |
| ● | Positive or negative | | | : | Automatic (no indication for a positive temperature) | | | |
| | temperature indication | | | (-) sign for a negative temperature | | | | | | | | | |
| ● | Display | | | | | | | | : | 4 ½ digits with LCD backlighted display | | | | | | | |
| ● | Auto-extinction | | | | | : | Automatic after 7 seconds of inactivity | | | | | | | | |
| ● | High/low alarm | | | | | : | Flashing signal on display and beep signal | | | | | | | |
| | with adjustable thresholds | | | | | | | | | | | | | | | | | | | | | | |
| ● | Power supply | | | | | | : | Alkaline 9V battery | | | | | | | | | | | | | | |
| ● | Autonomy | | | | | | | | 38 h (inactive laser and backlight) | | | | | | | | | |
| | | | | | | | | | | | | 15 h (active laser and backlight) | | | | | | | | | | |
| ● | Use temperature | | | | : | From 0 to +10°C for a short period | | | | | | | | | |
| | | | | | | | | | | | | From 11 to +50 °C for a long period | | | | | | | | | |
| ● | Storage temperature | | | : | From -20°C to +60°C | | | | | | | | | | | | | |
| ● | Relative humidity | | | | : | From 10% to 90%RH in operating mode and >80%RH in storage |
| ● | Dimensions | | | | | | | : | 175 x 110 x 45 mm | | | | | | | | | | | | | | |
| ● | Weight | | | | | | | | : | 230 g (included battery) | | | | | | | | | | | | |
| ● | Memory | | | | | | | | : | 20 temperature values with unit of measurement (°C or °F) |
| Thermocouple K probe | | | | | | | | | | | | | | | | | | | | | | | | |
| ● | Temperature range | | | : | From -40 to +400°C | | | | | | | | | | | | | | |
| ● | Display range | | | | | | : | From -50 to +1370°C | | | | | | | | | | | | | |
| ● | Resolution | | | | | | | : | 0.1°C | | | | | | | | | | | | | | | | | | |
| ● | Accuracy | | | | | | | : | ±1.5% of reading ±3°C | | |